Commonwealth was built inside a single, narrow window, which makes it unusually predictable. Kitchen and bathroom ground-fault protection as built; no arc-fault protection at all; and service equipment that has now been in place for three to four decades.
Most of this site is about establishing which era a house belongs to. Commonwealth is the exception: built out between 1987 and 1996, it sits entirely inside one code environment. Kitchen counter ground-fault protection had just become a requirement in 1987, joining outdoor (1971), bathroom (1975) and garage (1978), so the coverage picture is consistent street to street.
Equally consistent is what is missing. The bedroom arc-fault requirement took effect on 1 January 2002, six years after the last Commonwealth house was finished, so no house here has arc-fault protection as built. Laundry ground-fault protection (2005) and dishwasher protection (2014) came later still.
The aluminum branch wiring window closed more than a decade before construction started, so that question does not arise. See aluminum wiring remediation for why the dates matter.
Not obsolete by brand, simply old — and usually full, because thirty years of additions have used every space. See panel upgrades.
No compliance obligation exists, but a 1991 bedroom circuit has spent three decades in a hot attic. That is a reason on its own.
Original 1990s devices that no longer trip on test. A device that will not trip is no longer protecting anything, and it looks identical to one that works.
Circuits touched come up to the 2023 NEC as adopted here, which is why the quote includes breakers the house never had.
Standard construction practice through this era, and a common cause of three dark rooms and one bad device. See outlets, switches and fixtures.
Second systems, pools, home offices, chargers. The panel is rarely the constraint people expect; the service calculation is.
Commonwealth is inside the City of Sugar Land, so electrical work is permitted and inspected by City Building Standards under the 2024 International Codes and 2023 NEC. Confirm a specific requirement on (281) 275-2270.
Service work involves CenterPoint for the meter and disconnect and the City's Residential Pre-Release for Electricity process, with its next-business-day inspection before power is restored.
The FBCAD record confirms the build year for the address, though in Commonwealth the answer is rarely a surprise.